Page 52 - California Stormwater Workshop Handouts
P. 52

Industrial General Permit Order

C. Methods and Exceptions

1. The Discharger shall comply with the monitoring methods in this General
    Permit and Attachment H.

2. pH Methods

a. Dischargers that are not subject to Subchapter N ELGs mandating pH
    analysis related to acidic or alkaline sources and have never entered
    Level 1 status for pH, are eligible to screen for pH using wide range
    litmus pH paper or other equivalent pH test kits. The pH screen shall be
    performed as soon as practicable, but no later than 15 minutes after the
    sample is collected.

b. Dischargers subject to Subchapter N ELGs shall either analyze samples
    for pH using methods in accordance with 40 Code of Federal
    Regulations 136 for testing storm water or use a calibrated portable
    instrument for pH.

c. Dischargers that enter Level 1 status (see Section XII.C) for pH shall, in
    the subsequent reporting years, analyze for pH using methods in
    accordance with 40 Code of Federal Regulations 136 or use a calibrated
    portable instrument for pH.

d. Dischargers using a calibrated portable instrument for pH shall ensure
    that all field measurements are conducted in accordance with the
    accompanying manufacturer’s instructions.

3. Alternative Discharge Locations

a. The Discharger is required to identify, when practicable, alternative
    discharge locations for any discharge locations identified in accordance
    with Section XI.B.4 if the facility’s discharge locations are:

i. Affected by storm water run-on from surrounding areas that cannot
      be controlled; and/or,

ii. Difficult to observe or sample (e.g. submerged discharge outlets,
      dangerous discharge location accessibility).

b. The Discharger shall submit and certify via SMARTS any alternative
    discharge location or revisions to the alternative discharge locations in
    the Monitoring Implementation Plan.

4. Representative Sampling Reduction

a. The Discharger may reduce the number of locations to be sampled in
    each drainage area (e.g., roofs with multiple downspouts,
    loading/unloading areas with multiple storm drains) if the industrial

Order 2014-0057-DWQ        44